TOMY Japan SX-Series Vertical Autoclaves are offered by CSI Labshop Malaysia
CSI Labshop Malaysia has a comprehensive lineup of TOMY Japan SX-series vertical autoclaves designed for sterilization of media, equipment, samples, with automatic drying cycles and rapid cooling only available in TOMY autoclaves SX-series. We offer full installation, training, and commissioning setups anywhere in Malaysia. Trust our competent team to handle your autoclave needs for your laboratory. We also handle DOSH (JKKP approval and renewal) for customers. Our products come with complete service backup with TOMY renowned quality and reliability.
Autoclaves SX series LineUP
-
- SX-300
- SX-500
- SX-700
-
- SX-300E
- SX-500E
- SX-700E
Speedy Autoclaves
Maximized chamber capacity at Minimum installation space
Easy operation using the “Top-open lid”
A top-open lid, which can be operated easily with a single hand or foot, is provided with the SX autoclaves. To open the lid, the lid lock is released by stepping on the foot pedal locates at the bottom while pressing the lid down. The lid can be opened with minimal effort owing to mechanical assistance. In addition, the lid can be closed easily just by pressing it down.
Saving the installation space
The main body is very compact owing to the design which provides thorough installation space saving. In addition, installation space at the side of the main body which is required for models employing a slide-open lid, which is not necessary at SX autoclaves top-open lid. Even when several SX autoclaves are installed side-by-side, the necessary installation space is minimized.
A : 790mm(SX-300),970mm(SX-500),1003mm(SX-700)
B : 614mm(SX-300),794mm(SX-500),827mm(SX-700)
C : 410mm(SX-300/500),470mm(SX-700)
Easily viewable “work monitor”
The LED display shows working status for easy monitoring. The process being performed is indicated by an LED indication lamp blinking in red.
The illuminated display on the operating panel shown in the picture is different from the actual display at the time of operation.
Cooling fan provided as a standard feature
A rapid air-cooling function (vessel-cooling fan) permitting reduction of chamber cool down time is provided as a standard feature. This is most appropriate for lowering the temperature rapidly on completion of the cycle. The time required for lower the temperature is much reduced by employment of the cooling fan in comparison with natural cooling.
Sterilizing course selection
The optimal sterilizing course can be selected from among five courses, such as the liquid sterilizing course in addition to that for normal sterilization.
Other features
Large indication lamp “Operated”
An easily viewable large indication “Operated” is provided at the upper section of the operating panel.
Depending on the pressure status (normal pressure/pressure is applied),the displayed color changes.
Setting to 100°C is possible.
Variable temperature setting such as to 100°C as well as to 121°C has been made possible.The temperature can be set within the range from 45°C to 135°C in steps of one degree (heating mode up to 104°C).
Auto-variable exhaust speed
A function allowing the exhaust valve to open automatically after completion of sterilization is provided. The exhaust speed can be set to one of six levels (set to variable for liquid sterilization)
Timer function
The operation starting time can be preset easily. By presetting the start of operation, otherwise wasted periods at night or early morning, can be used effectively.
Setting to 100°C is possible.
Variable temperature setting such as to 100°C as well as to 121°C has been made possible.The temperature can be set within the range from 45°C to 135°C in steps of one degree (heating mode up to 104°C).
Lid interlock
A safety device (lid interlock mechanism) for locking the lid during operation is provided. A high level of safety is assured to prevent unanticipated accidents.
Pressure fine adjustment function
When the balance between the temperature and pressure deviates during sterilization, fine exhausting is carried out automatically in order to adjust the best chamber condition.
Functions & Features
Liquid sterilizing / Heating / Warming / Check / Last-run memory / Built-in steam exhaust bottle
Flat internal surface of the chamber / Lid opening/closing detection mechanism
Exhaust bottle detection mechanism / Leakage breaker provided
OPTION
External sensor for the articles to be sterilized
Sensor for directly detecting the temperature of articles to be sterilized. More reliable sterilization monitor can be carried out.
Data output
The temperature data, pressure data, etc. can be exported. The temperature can be recorded when the external recorder is connected.
External sensor and recorder
A temperature sensor and recorder independent of the autoclaves. The chamber temperature can be recorded.
SX Specifications
Model name | SX-300 | SX-500 | SX-700 | ||
Operating temperature range | Sterilizing | 105 ∼ 135°C(0.019 ∼ 0.212MPa) | |||
Heating | 45 ∼ 104°C(0 ∼ 0.015MPa) | ||||
Warming | 45 ∼ 95°C | ||||
Maximum operating pressure | 0.263MPa | 0.25MPa | |||
Temperature | Display | Digital | |||
Pressure gauge | Display | Analog | |||
Display range | 0 ∼ 0.4MPa | ||||
Heat source | 1.5kW electric heater | 2kW electric heater | 3kW electric heater | ||
Safety device | • Water level sensor, • Current leakage breaker, • Lid interlock, • Over-heat prevention, • Over-pressure prevention, • Open temperature sensor detection, • Safety valve | ||||
Time | Display | Digital | |||
Display range |
Sterilizing | 0:00 – 9:59, 0 – 99hours, 0 – 999min.(0:00 – 9:59,10 – 99hours changeable) | |||
Heating | |||||
Warming | Variable: 0 – 99hours | ||||
Chamber dimensions | φ325 x 553mm | φ325 x 733mm | φ370 x 774mm | ||
Chamber capacity | Effective internal volume:36L, Internal volume:44L |
Effective internal volume:50L, Internal volume:58L |
Effective internal volume:69L, Internal volume:79L |
||
Chamber material | SUS304 | ||||
Dimensions (mm) | 410W x 477D x 790Hmm (With protruding:574D) |
410W x 477D x 970Hmm (With protruding:574D) |
470W x 528D x 1003Hmm (With protruding:625D) |
||
Weight | 50kg | 60kg | 72kg | ||
Rated voltage | 120V AC | – | |||
230V AC | |||||
Power input | 13A/120V | 17A/120V | – | ||
7A/230V | 9A/230V | 13A/230V | |||
Required power supply | Single-phase 120V AC (50/60 Hz)15A or more |
Single-phase 120V AC (50/60 Hz)20A or more |
– | ||
Single-phase 230V AC (50/60 Hz)10A or more |
Single-phase 230V AC (50/60 Hz)15A or more |
Single-phase 230V AC (50/60 Hz)15 A or more |
|||
Power consumption (calorific value) | 1.5kW (1290kcal/h) | 2.0kW (1720cal/h) | 3.0kW (2580cal/h) | ||
Environmental Conditions | When opereting the autoclave, observe the environmental conditions given below. Ambient temperature: 10 to 35°C Almospheric pressure: 860 to 1060hPa Relative humidity: 30 to 85% Maximum gradient: 2 |
||||
Accessories | Stainless baskets 1 (φ300 x 182mm) |
Stainless baskets 2 (φ300 x 182mm) |
Stainless baskets 2 (φ345 x 181mm) |
||
• Chanber bottom Plate 1, • Caster stoppers 4, • Operator’s Manual 1, • Clear folder (for storing the operation manual) 1, • Screw (for attaching the clear folder) 1, • Warranty card 1, • Customer card 1, • Inspection Sheet 1 |
SX-E Specifications
Model name | SX-300E | SX-500E | SX-700E | ||
Operating temperature range | Sterilizing | 105 ∼ 135°C (0.019 ∼ 0.212MPa) | |||
Heating | 45 ∼ 104°C (0 ∼ 0.015MPa) | ||||
Warming | 45 ∼ 95°C | ||||
Maximum operating pressure | 0.263MPa | 0.25MPa | |||
Temperature | Display | Digital | |||
Pressure gauge | Display | Analog | |||
Display range | 0 – 0.4MPa | ||||
Heat source | 1.5kW electric heater | 2.0kW electric heater | 3.0kW electric heater | ||
Safety device | • Water level sensor, • Leakage breaker, • Lid interlock, • Over-heat prevention, • Over-pressure prevention, • Temperature sensor break detection, • Safety valve | ||||
Protection type against electrical shock | Class I equipment | ||||
Time | Display | Digital | |||
Display range |
Sterilizing | 0:00 – 9:59, 0 – 99hours, 0 – 999min.(0:00 – 9:59,10 – 99hours changeable) | |||
Heating | |||||
Warming | Variable: 0 – 99hours | ||||
Pressure chamber type | PED Category II | ||||
Chamber dimensions | φ325 x 553mm | φ325 x 733mm | φ370 x 774mm | ||
Chamber capacity | Effective internal volume:36L, Internal volume:44L |
Effective internal volume:50L, Internal volume:58L |
Effective internal volume:69L, Internal volume:79L |
||
Chamber material | SUS304 | ||||
Dimensions (mm) | 410W x 477D x 790Hmm (With projection:574D) |
410W x 477D x 970Hmm (With projection:574D) |
470W x 528D x 1003Hmm (With projection:625D) |
||
Weight | 50kg | 60kg | 72kg | ||
Rated voltage | 230V AC | ||||
Power input | 7A | 9A | 13A | ||
Required power supply | Single-phase 230V AC (50/60 Hz)10 A or more |
Single-phase 230V AC (50/60 Hz)15 A or more |
Single-phase 230V AC (50/60 Hz)15 A or more |
||
Power consumption (calorific value) | 1.5kW(1290kcal/h) | 2.0kW(1720kcal/h) | 3.0kW(2580kcal/h) | ||
Environmental Conditions | When opereting the autoclave, observe the environmental conditions given below. Ambient temperature: 10 to 35°C Almospheric pressure: 860 to 1060hPa Relative humidity: 30 to 85% Maximum gradient: 2 |
||||
Accessories | Stainless baskets 1 (φ300×182 mm) |
Stainless baskets 2 (φ300×182 mm) |
Stainless baskets 2 (φ345×181 mm) |
||
• Caster stopper 4, • Chamber bottom Plate 1, • Operator’s Manual 1, • Clear Plastic Accessory Case 1, • Attachment Screw for Clear Plastic Accessory Case 1, • Inspection Sheet 1, • Warranty card 1, • Customer card 1 |
*Please refer to the「 EC Declaration of Conformity」for detailed standard application.